Fast piezo shutters

CEDRAT TECHNOLOGIES (CTEC), specialized in mechatronics systems, has developed a specific products range for the synchrotron applications.

  • The Fast Piezo Shutters FPS and FAPS have been developed to provide with very fine and repeatable X Ray pulses in the optical path of the continuous X Ray beamline,
  • The Vacuum box: CTEC has developed a fully integrated solution for FPS and FAPS products in Vacuum Environments.

To obtain more information on our products feel free to ask for our Piezo & Magnetic Products Catalogue and/or contact us.

Fast Amplified Piezo Shutter - FAPS400M

  • STEP icone
  • PDF icone
  • Email icone
Description
The FAPS400M is a fast shutter solution for X-Ray beamline with large aperture / stroke capability (> 3mm) and short response time (< 8 ms). It is based on two APA400M® each one connected to and actuating a mechanical amplifier or a lever arm.
Performances
Full aperture (mm) 3; Response time (ms) 8; Max blocking W thickness (mm) 3.
Options disponibles
Vacuum (VAC)-Ultra High Vacuum (UHV)-Strain Gauge sensor (SG)
Status
Standard
Fast Amplified Piezo Shutter picture

Fast Piezo Shutter - FPS200M

  • 2D icone
  • PDF icone
  • Email icone
Description
The Fast Piezo shutter developped by CEDRAT TECHNOLOGIES in collaboration with EMBL (Dr. Cipriani) is based on standard amplified piezo actuators with a special optical head. It provides a compact and low jitter shutter solution for X ray beam.
Performances
Max No-load displacement (µm): 400; Dimensions (mm): 21*60*44; Unloaded resonance frequency (Hz): 900; Response time (ms): 0,56
Options disponibles
Strain Gauges; Vacuum
Status
Standard
Fast Piezo Shutter picture

Fast Piezo Shutter - FPS200M-SIW

  • 3D icone
  • 2D icone
  • PDF icone
  • Email icone
Description
The Fast Piezo shutter developped by CEDRAT TECHNOLOGIES in collaboration with EMBL (Dr. Cipriani) is based on standard amplified piezo actuators with a special optical head. It provides a compact and low jitter shutter solution for X ray beam.
Performances
Max No-load displacement (µm): 400; Dimensions (mm): 21*60*44; Unloaded resonance frequency (Hz): 900; Response time (ms): 0,56
Options disponibles
Strain Gauges; Vacuum
Status
Standard
Fast Piezo Shutter picture

Fast Piezo Shutter - FPS400M

  • PDF icone
  • Email icone
Description
The FPS400M (derived from FPS200M) is based on standard amplified piezo actuators APA 400M with a special optical head. The FPS 400M is a compact, low jitter and high stroke shutter solution.
Performances
Max No-load displacement (µm): 800; Dimensions (mm): 21*60*44; Unloaded resonance frequency (Hz): 430; Response time (ms): 1,16
Options disponibles
Strain Gauges, Vacuum
Status
Standard
Fast Piezo Shutter picture

Fast Piezo Shutter - FPS400M-SIW

  • 3D icone
  • 2D icone
  • PDF icone
  • Email icone
Description
The FPS400M (derived from FPS200M) is based on standard amplified piezo actuators APA 400M with a special optical head. The FPS 400M is a compact, low jitter and high stroke shutter solution.
Performances
Max No-load displacement (µm): 800; Dimensions (mm): 21*60*44; Unloaded resonance frequency (Hz): 430; Response time (ms): 1,16
Options disponibles
Strain Gauges, Vacuum
Status
Standard
Fast Piezo Shutter picture

Fast Piezo Shutter - FPS900M-SIW

  • 3D icone
  • 2D icone
  • STEP icone
  • PDF icone
  • Email icone
Description
The FPS900M (derived from FPS200M and 400M) is based on standard amplified piezo actuators APA 900M with a special optical head. The FPS 900M is a compact, low jitter and high stroke shutter solution.
Performances
Max. No-load displacement (µm): 1600; Dimensions (mm): 23*60*44; Unloaded resonance frequency (Hz): 200; Response time(ms): 2.50ms
Options disponibles
Strain Gauges, Vacuum
Status
Standard
Fast Piezo Shutter picture

Vacuum box

  • Email icone
Description

CTEC has developed a fully integrated solution for FPS and FAPS products in Vacuum Environments. The Shutter is mounted inside the Box with vacuum cable feedtrought. The shutter can be unmounted and mounted again without removing the Vacuum Box from the beamline.

Performances
Vacuum box with KF40 interface
Status
Standard
Vacuum box picture